T400 Controller Facilities Manual
667/EB/20200/000 Page 9-39 Issue 9
9.7 MANUAL STEP-ON MODE
A Manual Step-on facility can be provided when a Police Manual Panel is fitted. See
Figure 9.4.
If the Manual Step-on facility is used and located behind the Manual access flap on the
side of the controller, the Manual facility described in section 9.6 is transferred to the
internal manual panel.
It is possible to change stage under Manual Step-on Control by operation of a push
button on the Police Manual Panel. When Manual Step-on has been selected on the
Police Manual Panel, the controller, subject to the Mode Priority, will go into Manual
Step-on Mode. The order in which stages are introduced in Manual Step-on is
predefined in configuration (site data). The push button on the Police Manual Panel is
operated to make the controller move on to the next designated stage. Having arrived
at the next stage the controller may do one of two things depending on the option
selected.
(a) Remain in that stage indefinitely, the controller being ready to respond to
another operation of the push button, which if operated will send the controller
to the next predefined stage,
or
(b) stay in one stage for a fixed period defined at configuration and then
automatically move to another pre-defined stage. The controller is then ready
to respond to a further push button operation.
The user may change the operation between (a) and (b) as required, by means of the
handset.
There is a separate Push Button for selecting All Red. When this Push Button has been
operated the controller will, subject to any safety periods, change to the All Red stage.
The controller will stay in the All Red stage until the Manual Step-on Push Button is
operated when the controller will move to the next stage in the cycle following the
stage prior to the call to the All Red stage. Alternatively, if the manual mode is
switched off the controller moves to the stage required in the new mode.
The Manual mode should be disabled after use by operating the Manual Disable
pushbutton.
9.7.1 Manual Disable Switch (Police)
A micro-switch may also be fitted to the Police manual step-on panel to disable manual
step-on mode when the door is closed. If the manual panel is subsequently opened,
manual step-on mode is not re-entered; to select manual step-on mode it is necessary
to operate the Enable push button.