T400 Controller Facilities Manual
667/EB/20200/000 Page 25-4 Issue 9
25.1.2 PHYSICAL DESCRIPTION
25.1.2(a) Mechanical Construction
The PCB is located within the T400 PCB Module, along side the other T400 Logic
PCB’s. It interfaces to the T400 Main Processor PCB via the Extended System Bus
ribbon cable, in a similar way to the existing SDE/SA PCB.
25.1.2(b) Current Sensors & Voltage Monitor
There is a connector on the PCB to allow connection of the current sensors and a
voltage monitor which are used for Lamp Monitoring.
25.1.2(c) Telephone Line Interface (OTU)
There is a BT style Jack provided to allow 2 or 4 wire leased line connection, when
used as an integral OTU.
25.1.2(d) Test Jack Sockets (OTU)
A Jack socket is provided to allow connection of a TC12 Instation Test Set, for use in
UTC systems. This permits monitoring of line levels and communication data during
installation and maintenance etc.
25.1.3 ANCILLARY PROCESSOR PCB ELECTRONICS
The Ancillary Processor PCB is based on the Intel 80188 microprocessor, which is the
same processor as used on the T400 Main Processor PCB. Please refer to Figure 25.1
for a functional block diagram of the Ancillary Processor PCB.
The peripherals to the processor are the:
Firmware PROM
RAM (battery supported)
Shared RAM (‘shared’ with the T400 main processor)
A to D Converter with Analogue Multiplexer
Serial Interface (USART) with integral Modem and Line Interface
Watchdog Monitor Facility
Status LED Indicators
Note that there is no configuration prom on this PCB as all the data is obtained from
the T400 configuration prom.