T400 Controller Facilities Manual
667/EB/20200/000 Page A-9 Issue 9
Table APPENDIX A) -14) Cable Distances for SDE using Sarasota Detectors (2
CHANNEL)
Cable length from stop line to controller = n’ metres
Cable 1mm
2
= 0.0362 Ohm/metre loop
Supply Voltage for Detectors = 21V - 40V
Detector PSU Output Voltage = 27.5V+4.5% (Max 28.74V, Min
26.26V)
Max permissible volt drop (27.5V PSU) = 5.26V
Logic PSU = 24v+6% (Max 25.44V, Min 22.56V)
Max permissible volt drop (24V supply) = 1.56V
Cable Length ‘n’
power supply: 27.5v P.S.U. 24v P.S.U.
current per 2 channel card: 230mA 160mA 230mA 160mA
3-lane 1 conductor out & return unusable 24 unusable unusable
3-lane 2 conductors out & return 85 177 unusable unusable
2-lane 1 conductor out & return 32 41 unusable unusable
2-lane 2 conductors out & return 147 329 unusable 9
1-lane 1 conductor out & return 190 329 unusable 9
1-lane 2 conductors out & return 506 780 62 144