T400 Controller Facilities Manual
667/EB/20200/000 Page 10-2 Issue 9
10.1 PROHIBITED MOVES
When a move to a stage is prohibited and there is a demand for the prohibited stage,
the controller will not move to that stage and the current stage will remain active until
either of the following happens:
(i) the stage change conditions alter and a move can be made to a stage
before the prohibited stage.
(ii) the stage change condition is removed and replaced by another stage
change condition.
(iii) the stage change restriction is removed due to a mode change.
In (i), after the stage change occurs, a move to the original prohibited stage might now
be permitted.
In (ii), the only modes that could achieve this are:
Manual - by the operator seeing the prohibited move light illuminated and
selecting another stage by means of the appropriate push-
button.
UTC - by the force being removed and another one applied.
CLF - by another group influence becoming active.
In the example in Figure 21.6(a), the move 2-1 is prohibited in Manual mode, because
the indicative green arrow Phase C must terminate with Phase B (see section 3.2.3(b)),
and the move 4-3 is prohibited because of the required method of control.
10.2 ALTERNATIVE MOVES
When a move is not allowed it may be possible to specify an alternative move to a
nominated stage. The stage may either be one that is in general use or one that is used
only for the alternative move.
If the nominated stage is in general use, any move out of it will be subject to any
current stage change conditions and may not go directly to the original required stage.
If the nominated stage is used only for the alternative move then the only permitted
move to it will be from the original current stage and the only move out of it will be to
the original required stage. All other moves out of it will be restricted by specifying an
alternative move to the original required stage. This will ensure that the original
required stage is reached before any other stage change conditions are satisfied.
In the example in Figure 21.6(a), the move 4-3 is not allowed, but an alternative move
into stage 1 is required in VA, UTC and CLF modes. When Stage 1 gains ROW there
Vista de pagina 122