T400 Controller Facilities Manual
667/EB/20200/000 Page 9-59 Issue 9
9.12 MODE PRIORITY
The mode priority facility allows for the mode with the highest priority for which
operating conditions are active (e.g. force bits from the UTC computer or a hurry call
demand) to be the current mode. When the operating conditions become inactive, then
the next highest priority mode with operating conditions active will become the current
mode. It need not necessarily be the next one in line. If at any time operating
conditions for a higher priority mode become active, then that mode will become the
current mode. If more than one set of operating conditions are active then the mode
with the highest priority will become the current mode.
In order to achieve this facility, the mode select buttons on the manual panel are left in
the NORMAL position.
The current mode may be read via the handset using the MOD command.
If VEHICLE ACTUATED mode is in the priority list then this must be put as the
lowest priority. If VA mode is not required then FIXED TIME mode must be the
lowest priority.
For priority purposes, SELECTED MANUAL CONTROL and SELECTED FIXED
TIME, CLF OR VA are considered as modes. The operating conditions for these
modes are the relevant mode select buttons being selected, i.e. MANUAL, FIXED
TIME, CLF or VA.
Fixed time, CLF or VA selected via the manual panel are considered as different
modes tonormal’ VA, CLF or Fixed time modes. This allows VA or Fixed time to be
configured as the lowest mode, i.e. the one in which the controller will operate if no
higher priority modes are requested. Whilst SELECTED VA or FIXED TIME mode
can be configured higher up the mode priority table, so that if necessary, the controller
can be forced to operate in VA or Fixed time, even if there are requests for modes of
higher priority than the basic VA or Fixed time.
e.g.
Priority Mode(s)
1 Selected VA, CLF or fixed time*
2 Hurry
3Priority
4UTC
5CLF
6VA
(* This will allow controller to be forced to operate in the Selected mode even if any of
modes 2-4 are requested to be active).
To select Fixed Time, CLF or VA, the appropriate mode select button on the manual
panel must be selected.