T400 Controller Facilities Manual
667/EB/20200/000 Page 19-11 Issue 9
19.4 SET UP CONNECTIONS FOR RED LAMP MONITORING
Installation is in accordance with Lamp Monitoring Unit Handbook
667/HB/17330/000 Section 5. The pre-installation are detailed in Section 4 and should
be as follows:
19.4.1 Link Pin Connections
Output State Watchdog fail:- LINK 1 Pins 1 and 3 (standard - Open CCT)
Mains Voltage Supply:- LINK 7 Pins 2 and 3 (for 240v)
Watchdog Retry Count:- LINK 11 Pins 1 and 4 (standard - 7 Retries)
19.4.2 Configuration Switch (SW1)
(See Handbook Section 4.4 for full details)
BIT No.76543210
SWITCH No.87654321
ON or OFF11111000
A CLOSED (ON) SWITCH = 0
AN OPEN (OFF) SWITCH = 1
SWITCH 6 / BIT No. 5
When SWITCHED SIGNS are being monitored this switch is set CLOSED otherwise
set it OPEN.
19.4.3 LMU Output Connections To Controller Inputs
LMU
Connection
PL4
LMU
Output
T400
Input
Terminal
Input
Reference
MCK1061
Reference
Pin 1 (+ve) 0 SEE LMU1 INDICATION 1
Pin 3 (+ve) 1 WORKS LMU2 INDICATION 2
Pin 5 (+ve) 2 SPEC. LMU3 INDICATION 3
Pin 2 (-ve)
Pin 4 (-ve) Linked Together & Connected to T400 Terminal TN3 and TN4
Pin 6 (-ve)