Vista de pagina 300
T400 Controller Facilities Manual
667/EB/20200/000 Page A-5 Issue 9
Appendix APPENDIX A) .3) Using 27.5v Additional Detector PSU
Where there is insufficient spare capacity on the 24v power supply the 27.5v supply
must be called up. (Table APPENDIX A) -6 to Table APPENDIX A) -8)
The distance rules are different for this supply as the allowable voltage drop is greater
due to the higher supply voltage;- see Table APPENDIX A) -9 to Table APPENDIX
A) -12.
Table APPENDIX A) -6) 4-Channel Detector Cards
Maximum No. of 4-Channel Cards
Siemens or
Microsense Sarasota
(220mA) (370mA) (160mA)
Small PSU 667/7/20204/001 (2A) 7 4 9
Large PSU 667/7/20204/000 (4A) 13 8 18
Table APPENDIX A) -7) 2-Channel Detector Cards
Maximum No. of 2-Channel Cards
Siemens or
Microsense Sarasota
(220mA) (370mA) (160mA)
Small PSU 667/7/20204/001 (2A) 7 6 9
Large PSU 667/7/20204/000 (4A) 15 13 18
Note:
2 Channel Detector cards are usually used for SDE/SA
see Manufacturers information.
Table APPENDIX A) -8) 24v +/-20% 8VA (333mA) Above Ground Detectors
Max. No. of Detectors
Small PSU 667/7/20204/001 (2A) 6
Large PSU 667/7/20204/000 (4A) 12