T400 Controller Facilities Manual
667/EB/20200/000 Page 14-2 Issue 9
If this sequence is required, the pedestrian phase has to be programmed as a traffic
phase in order to obtain the amber signal. If a wait indicator is required, this has to be
programmed as a switched sign phase (see section 3.2.5(b)).
Green must always be used forat right-of-way” for traffic, pedestrian & green arrow
phases because of the green conflict facility.
14.2 ALTERNATIVE START-UP SEQUENCES
As an alternative to the standard start-up sequence and blackout during Part-time
mode, the following may easily be provided as stated in above statement.
(a) Start-up Sequence
FLASHING AMBER for 6 seconds
ALL-RED for the length of the starting intergreen plus the amber leaving time.
With ROW going first to Stage 1 before completing one cycle.
(b) Part-Time Mode
At the changeover to Part-time mode, following the expiry of all phase
minimum greens, ROW goes to an all-red stage (normally Stage 0) for a
specified time. This is then followed by flashing amber to all traffic phases and
blackout to all pedestrian and green arrow phases.
The specified time in the all-red stage is provided by allocating a dummy phase
to the stage. The minimum green value of the dummy phase will provide the
time.
At the changeover from Part-time mode the start-up sequence is effective.
(c) Other Modes
The signal sequence during all other modes remains the same as the standard
sequence unless requested to be changed.