T400 Controller Facilities Manual
667/EB/20200/000 Page 18-1 Issue 9
18. EQUIPMENT
18.1 PHASE FACILITIES
The Intersection Controller can drive up to 16 real phases. The Pelican can drive a
traffic and a pedestrian phase. The signals are driven by 4-Phase Driver Boards on the
Intersection Controller and 2-Phase Driver Boards on the Pelican. A 4-Phase Driver
Board drives four 3-aspect phases and a 2-Phase Driver Board drives two 3-aspect
phases with a MCE 0125/MCE 0145 Red Lamp Monitor circuit.
A real phase can control one of the following:
(i) vehicle movements via a 3-aspect signal
(ii) pedestrian movements via a 2-aspect signal and a WAIT indicator
(iii) vehicle movements via a green arrow signal.
(iv) a switched sign.
18.2 MAIN CONTROLLER UNITS
667/1/20200/000 Type 400 Controller (Large, small and options).
667/1/20240/000 Large Case Preliminary Assembly.
667/1/20240/100 Small Case Preliminary Assembly.
667/1/20284/001 Controller Manual Panel Assembly.
667/1/20284/002 Pelican Manual Panel Assembly.
667/1/20221/001 Main Processor PCB.(Intersection use.)
667/1/20221/002 Main Processor PCB.(Pelican use.)
667/1/20223/000 4 Phase Driver PCB
667/1/20225/000 2 Phase Driver + Red Lamp Monitor PCB.
667/1/20229/000 Expansion I/O PCB.
667/1/20231/000 SDE/SA PCB.