T400 Controller Facilities Manual
667/EB/20200/000 Page 16-2 Issue 9
16.1.6 DFM Reset Push-button (If Configured)
The DFM RESET push-button extinguishes the CABINET ALARM lamp, providing
the DFM failure causing the alarm indication has been cleared. This push-button also
re-establishes fault monitoring for detector inputs overridden via the handset using the
ADF command.
16.1.7 Lamp Test Push-button
The LAMP TEST push-button applies a signal which illuminates all indicators on the
Manual panel and illuminates the CABINET ALARM lamp for test purposes.
16.1.8 Manual Button Indicators
The Manual Button Indicators are for use during Manual mode. They generally
indicate the number of the current stage selected, but see section 9.6.2.
These indicators are only illuminated when manual mode is in operation or when the
handset is plugged in.
16.1.9 Awaiting Command Indicator
When Manual mode is operative, the AWAITING COMMAND indicator illuminates
when a stage change is permitted, i.e. the minimum green periods for the phases in the
current stage have expired (see section 3.5.1).
16.1.10 Prohibited Move Indicator
When Manual mode is operative the PROHIBITED MOVE indicator illuminates if the
selected stage is prevented, deleted by the master time clock or if the move is
prohibited.
16.1.11 Hurry Call Active Indicator
This is illuminated immediately a valid Hurry Call is received and remains illuminated
until the end of the hold period even if Hurry Call mode is not the current mode due to
a higher priority mode being active.
16.1.12 Higher Priority (UTC) Active Indicator
This is illuminated whenever the current operating mode is higher priority than manual
mode (this could be due to UTC bus priority etc.).
16.1.13 Spare Indicators
There are three indicators (AUX1, AUX2, AUX3) whose function can be set up in
configuration, e.g. to indicate when an input to a Priority Unit is active, UTC active,
Remote Reconnect, Dim override, Alternative Maximum, Audio override, Barrier Up,
Continuous Demands and/or Extensions, Green Wave etc.