T400 Controller Facilities Manual
667/EB/20200/000 Page 18-6 Issue 9
18.12 POWERING EXTERNALLY SITUATED D-DETECTORS WITH PSU TYPE
667/1/20654/000
Items Required:
Kit Of Parts required ........................................................667/1/20659/000
This is an unregulated nominal 45 volt PSU option which may be retrofitted to a
Siemens T400L or T400S Traffic Controller to provide a DC supply for the old Type
D inductive loop detectors fitted in external housings (“beehives”).
This unit is a simple transformer isolated, capacitor-smoothed supply designed to fit
into a Type 400 controller. It consists of a single metal plate to which the electronic
items are fitted and interconnected by hand wiring.
Each beehive is equipped with a Regulator in addition to a number of detector cards.
Load Calculation
Maximum O/P current = 500 milliamps
Current per Regulator board = 16 milliamps (1 regulator per beehive)
Current per detector board = 48 milliamps