T400 Controller Facilities Manual
667/EB/20200/000 Page 17-6 Issue 9
17.6 WAIT INDICATORS
This facility allows the user to select (via the handset) whether the wait indicator is
illuminated by any of the following demands:
- Pushbutton ped demands
- UTC ped demands
- Manual Panel ped demands
- Local Link ped demands
- Handset ped demands
17.7 AUDIO CONTROL AND MONITOR
An output activates the audio unit during the ped. steady green time (MCE0125 only).
An input monitors the drive voltage to the audio unit and a check is made that the
monitored state corresponds with the requested state. Repeated failure of the check
causes the lamps to be turned off within 500mS (from the point at which the first
occurrence of the fault was detected) and an entry made in the fault log. Since the
audio drive is derived from the pedestrian green supply, turning the signals off removes
the audio drive.
These is one audible drive circuit per 2 phase driver board, and each can drive upto 6
audibles (assuming each is 2k).
In the interests of safety, when the audibles are off, one set of relay contacts ‘short’ the
cable pair driving the audibles, and the other set connects a 1k resistor across the
supply driving the audibles.
This audio drive can also be used to control Tactile Units, see Figure 18.3.
17.8 GREEN CONFLICT FAULT ACTION
On detection of a green conflict (as indicated by monitoring the output of the green
conflict PROM) the controller turns all the controller lamps and audio indicators off.
The lamps will remain off until manually reset, using the handset, turning the power off
and then restoring the power.
17.9 RED LAMP MONITORING
The each pelican stream has upto four seperately monitored vehicle red drives, known
as the four red lamp monitor ‘channels’. The current flowing through the vehicle red
lamps is monitored to check that there is at least one vehicle red lamp showing per
channel while there is a steady green signal showing to pedestrians. If a fault occurs,
the controller turns the signals and the audio indicators off for that pelican stream. The
lamps will remain off until manually reset, using the handset, turning the power off and
then restoring the power.