T400 Controller Facilities Manual
667/EB/20200/000 Page 12-1 Issue 9
12. THE EVENT TIMETABLE
12.1 PLAN CHANGE/EVENT TIMETABLE
There are 64 entries in the Event Timetable. Within each entry, the following 6 pieces
of information are specified.
1. The Day Type, which is a number that indicates the day(s) on which this Event
occurs.
Number Significance
0 Saturday
1 Sunday
2 Monday
3Tuesday
4 Wednesday
5 Thursday
6 Friday
7Every Day
8 Every Day except Sunday
9 Every Day except Saturday and Sunday
2. The Hours value at which the event is introduced.
3. The Minutes value at which the event is introduced.
4. The Seconds value at which the event is introduced.
5. The Time Switch Setting Command Code which indicates what function is to
be performed when this Time Switch Setting is reached. Possible Codes are
one of the following:
a) Isolate, i.e. Switch the controller to VA operation.
b) Selects the Plan number. The actual Plan number to be selected is
specified.
c) Change the Switch Function Settings to those as specified.
6. The extra information required for option b) and c) in 5 above.
12.2 CABLELESS LINK PLANS
The cableless link plans define the timing period for each group but the actual function
of the group is determined firstly by the group influence set which applies and secondly
by the group influence definition contained within the particular set.
Refer to Section 9.9 for CLF Mode operation.