T400 Controller Facilities Manual
667/EB/20200/000 Page 17-8 Issue 9
17.10.1 UTC Facilities (Control Bits)
UTC Ped. Inhibit (PV)
This input signal prevents the pedestrian phase on a pelican. When PV is released,
vehicle extensions will be inhibited for a period specified via the handset (UIE). Even if
PV is reapplied during this period it will have no effect.
UTC Ped. Demand (PX)
This input signal puts in a request for the pedestrian stage of a pelican.
Vehicle Extensions Inhibit (SC)
This input signal forces the controller to ignore all vehicle extension requests. To
ensure safety of operation, the vehicle to ped. change becomes a UTC. all-red change
rather than a gap change. The UTC all-red change time is alterable via the handset.
Real Time Clock Sync.
This input causes the Real Time Clock to synchronise to 12:00:00 hrs each day.
UTC Transmission Confirm (TC) or Takeover Control (TO)
The TC signal, if allocated to an I/O line, is transmitted to the controller from the OTU
if valid data has been received by the OTU. The TO signal is very similar in effect
except that it is transmitted from the UTC Central Office and not from the OTU and it
too signifies that valid data is being sent by the UTC Central Office. The presence of
either of these signals disables the Local Link facility.
Computer Control LED on the Manual Panel
The rules governing the illumination of this LED are as follows:
(1) If the TC/TO function has not been assigned to an IO Line then the presence of PV
alone lights this LED.
(2) If TO has been assigned to an I/O line then the LED is only illuminated when TO is
present in conjunction with PV.
(3) If TC has been assigned to an I/O line and selected to control the LED, then the
presence of this TC signal alone lights the LED.
(4) If TC has been assigned to an I/O line and selected not to control the LED, then
the LED is illuminated only when both PV and TC are present (as in case 2).
Switch to FVP mode
This input disables Pelican VA mode and thus forces the controller to run in FVP
mode. This signal only has an effect when the Pelican is running VA mode which
happens when:
(a) VA operation is selected via the handset.
AND (b) the mode requested by the VA select button on the manual panel is VA.