T400 Controller Facilities Manual
667/EB/20200/000 Page 20-3 Issue 9
Example
If a side road phase is extending towards its maximum and a demand is inserted for the
main road, providing the side road max timer has exceeded 20 seconds then the
extensions may be prevented, to allow the main road phase to gain ROW immediately.
Phase B at green and demand present for phase A?
YES NO
Phase B max timer > 20 ? Do nothing
YES NO
Prevent phase B extensions Allow phase B extensions
END
MAIN ROAD = PHASE A
SIDE ROAD = PHASE B
20.5 SPECIAL CONDITIONING WITH CONTROLLER CONFIGURING SYSTEM
(Supplied Separately from Controllers)
Within the controller configuring system (The Configurator) files containing special
conditioning code can be stored and used as a library. Allowing commonly used items
of special conditioning to be recalled for use at any time. For further details see the
Configurator Handbook.