T400 Controller Facilities Manual
667/EB/20200/000 Page 9-58 Issue 9
timer will start when all stages have appeared. This process will be repeated for each
configured stage combination, until either the last available (i.e. sixteenth) or last
configured stage combination is reached. In these cases stage combination 0 will
commence again.
During Linked Fixed time mode the controller will display fixed time mode on the
handset (Mode 1).
Fixed time mode need not be active on all streams. Only the streams that have fixed
time active will be demanded through the specified stage combination.
EXAMPLE
Four Streams with the following Stages allocated to each:
STREAM STAGES
0 0, 1, 2, 3
1 4, 5, 6
2 7, 8, 9
3 10, 11, 12
Where Stages 0, 4, 7 and 10 are All Red Stages.
If Streams 2 and 3 are to run independently in Fixed Time Mode, then Streams 0 and 1
could run the following linked sequence (for example):
STREAMS COMBINATION STAGES RUNNING TOGETHER
0 and 1 0 1 and 5
0 and 1 1 2 and 5
0 and 1 2 3 and 6