Keypads
99
Building Technologies
Fire Safety & Security Products
18.4 Keypad <Arm> Button options
Keypad ARM Areas
P74E 1-8E 1-2E
Option Display text Description
1
Area A
Area A: this option assigns the keypad button to Area A. If a keypad button is
assigned to only Area A it can only arm or disarm that area.
2
Area B
Area B: this option assigns the keypad button to Area B. If a keypad button is
assigned to only Area B it can only arm or disarm that area.
Keypad ARM Access
P75E 1-8E 1-8E
Option Display text Description
1
Can Arm
<Arm> button can arm: this option enables single button arming using the button.
For single button operation to work options 1 & 3 must be off at location P45E
2
Can Stay
<Arm> button can arm Stay Mode: this option enables single button arming of Stay
Mode using the
button. For single button operation to work options 1 & 3 must be
off at location P45E.
(NOTE: Following arming of Stay Mode, if the
button is pressed, all entry & exit
delays will be reset to zero for that armed period).
3
Open Anytime
<Arm> button can disarm at all Times: this option enables single button disarming
using the
button. For single button disarm operation to work options 1 & 3 must be
off at location P45E
4
Unstay Anytime
<Arm> button can disarm Stay Mode at all Times: this option enables single button
disarming of Stay Mode using the
button. For single button disarm operation to
work options 1 & 3 must be off at location P45E
5
Can Reset
Alarms
<Arm> button can reset Alarms: if this option is on, pressing the button (provided
Option 3 is also on) will reset an alarm condition without having to enter a user code.
6
Latch Key Option
<Arm> button can arm Latchkey Mode: this option enables single button arming of the
alarm in Latchkey report mode using the
button. For single button disarm
operation to work options 1 & 3 must be off at location P45E. When Latchkey Mode is
set on arming, any code without the Latchkey option (P4E Option 6) used to disarm
the alarm will cause a disarm report to be sent via the dialer.
7
Open on Exit
<Arm> button can disarm during Exit Delay: this option allows single button disarming
using the
button provided the Armed Mode exit delay is active. If the exit delay has
expired the
button cannot be used to disarm the alarm. For single button disarm
operation to work options 1 & 3 must be off at location P45E
8
Unstay on Exit
<Arm> button can disarm Stay Mode during Exit Delay: this option allows single
button disarming of Stay Mode using the
button provided the Stay Mode exit delay
is active. If the Stay Mode exit delay has expired the
button cannot be used to
disarm Stay Mode. For single button disarm operation to work options 1 & 3 must be
off at location P45E