Zones
116
Building Technologies
Fire Safety & Security Products
20.7 Zone alarms to output mapping
Zone Arm Outs
P128E 1-16E 1-8E
If an Area is Armed and a zone assigned to that Area activates, the zone can
trigger selected outputs for local alarm signaling. This location assigns Zones to
outputs for alarms that occur when in the Full Armed State.
Option 1 = Output 1; Option 2 = Output 2 etc.
Zone Stay Outs
P129E 1-16E 1-8E
If an Area has Stay Mode Armed and a zone assigned to that Area activates, the
zone can trigger selected outputs for local alarm signaling. This location assigns
Zones to outputs for alarms that occur when Stay Mode is armed.
Option 1 = Output 1; Option 2 = Output 2 etc.
Zone 24Hours Outs
P130E 1-16E 1-8E
If a zone is programmed as a 24 Hour type and it activates, the zone can trigger
selected outputs for local alarm signaling. If the zone is a standard 24 hour type
(P123E 3E) the output will turn for the full reset time, if it is an Auto-reset type
(P123E 4E) the output will either turn off when the reset time expires or if the input
clears and if it is a Fire type (P123E 5E) the output will pulse at a rate equal to the
pulse time for that output.
Option 1 = Output 1; Option 2 = Output 2 etc.
Zone Chime Outs
P131E 1-16E 1-8E
If a zone is programmed as a Chime zone (P123E 7E) and it activates, the zone
can trigger selected outputs for local alarm signaling. The output will operate for
the Chime to Output time at location P41E. The zone must clear before the output
can be activated again.
Option 1 = Output 1; Option 2 = Output 2 etc.
Zone Tamper Outs
P132E 1-16E 1-8E
If a hardwired zone is programmed to allow tamper monitoring (P125E types 12, 13
& 14), or the zone is a radio detector with tamper, the zone tamper can trigger
selected outputs for local alarm signaling.
Option 1 = Output 1; Option 2 = Output 2 etc.
Zone Near Alarm Output
P167E 1-16E 1-8E
If the option near alarm zone or confirmed alarm zone is activated (this could be
done only for a total Area. See chapter
17.1: Area arm and special function
options; Zone B Options; P46E 1-2E 1E) this location assigns zones to outputs for
alarms that occur when near alarm zone function is activated (pre alarm
information that could be used).
Option 1 = Output 1; Option 2 = Output 2 etc.