Siemens IC60 Manual de usuario Pagina 89

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 172
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 88
Areas
89
Building Technologies
Fire Safety & Security Products
17 Areas
17.1 Area arm and special function options
Area A Options
P45E 1-2E 1-8E
(1 = Area A, 2 = Area B)
Option Display text Description
1
ARM before
Code
<Arm> button Required Before Code to Arm: this option determines if the button
must be pressed before a code is entered to Arm an Area. If a User has access to
both Areas and this option is turned on, the special keypad arming or disarming
functions as described at chapter operating a Keypad, will apply.
2
Stay before Code
<Stay> button Required Before Code to Arm Stay Mode: this option determines if the
button must be pressed before a code is entered to Arm Stay Mode. If a User has
access to both Areas and this option is turned on, the special keypad arming functions
as described at chapter operating a Keypad, will apply.
3
Code required to
Arm
Code required to Arm: if this option is turned on, the button is disabled and the
panel requires a code to Arm.
4
Bypass required
Code
Code required to Bypass: if this option is turned on, the
button cannot access
Bypass Mode directly. To enter Bypass mode the User must press
, enter code and
press
before they can bypass zones.
5
-
Spare
6
Dial After Exit
Report Arm Signal at the end of the Exit Delay: if this option is on the panel will report
the arm signal to a monitoring station when the exit delay expires. If it is off, the panel
will report the arm signal immediately the system has been armed.
7
Arm if Secured
Can Arm only if All Zones Sealed (Ready): if this option is on it stops the panel from
arming an area with an unsealed zone (Not ready). If off, the panel can be armed if
the Ready LED is not on.
8
Stay if Secured
Can Arm Stay Mode only if All Zones Sealed (Ready): if this option is on it stops the
panel from arming stay mode if an area has an unsealed zone (Not ready). If off, the
panel can be arm stay mode if the Ready LED is not on.