Miscellaneous installer and panel options
78
Building Technologies
Fire Safety & Security Products
14 Miscellaneous installer and panel options
14.1 Miscellaneous panel options
Miscellaneous Options
P25E 10E1-8E
Option Display text Description
1 Tamper uses
EOL
Panel Tamper is 2k2 EOL: the tamper input (TMP) on the control panel requires either
a short circuit or a 2k2 End-of-Line resistor. If option 1 is on the panel must see a 2k2
resistor (EOL) across the TMP & 0V terminals to ensure the tamper is sealed. If this
option is turned off then a simple short circuit is all that is required to seal the panel
tamper.
2 Installer Direct Direct access to program mode for the Installer Code: if this option is on, the Installer
Code can gain access to Installer Program Mode directly. If the option is turned off,
the installer can only gain access to Installer Program Mode via Client Program Mode.
This option allows the owner to control program mode access by the installer. The
User must have option 3 at location P5E turned on for them to allow installer access.
3 Ignore AC Fail Disable Mains Fail Test: if the panel must be run off a DC supply or the Mains supply
can fail regularly, this option disables the mains voltage monitoring to prevent mains
fail alarms from occurring.(e.g. If used on a boat or camper by battery)
4 Output1 Low
Volume
Listen-in to Output # 1 Low Volume: if Listen-In to Output 1 is turned on (P175E 8E),
the level of sound from the speaker can be controlled with this option. If this option is
Off the sound level during listen-in to O/P 1 is high volume, turning this option On
makes the sound level low volume. For listen-in to Output 1 to work the device
connected to O/P 1 must be an 8Ώ speaker and the output must be modulated (P35E
1E Option 1 on). Failure to do this could result in damage to the speaker & output.
5 No Arm RF Fault Receiver Fail Lockout: if the receiver fail delay (P25E 7E) is set to a value other than
0 and the panel sees no activity from the receiver for the set period of time, a receiver
fail alarm will be generated. If this option is turned on, the panel cannot be armed until
the cause of the receiver failure has been resolved.
6 Output data to
bus
Send Output information to Keypad Bus: there is an optional 4 x relay output
expander board that can be connected to the keypad bus if required. For this output
expander to work option 6 must be turned on for the data to be sent on the keypad
bus to the expander.
7 No Arm AC-Low
Battery
Cannot Arm if System battery is Low: if the panel battery is low, normally you can arm
the panel leaving the battery to charge over a period of time. If this option is turned
on, the panel cannot be armed until the battery is either fully charged again, or it has
been replaced (if faulty).
8 Installer Lock Installer Lockout: normally if the panel is powered up with the panel tamper open (e.g.
system tamper alarm active) and in the Disarm state, then the panel will go into
installer program mode when the
P
r
og
then buttons are pressed. If this option is on,
the panel will not allow access to program mode on power-up and the only valid
method of accessing program mode is via the installer code.