Telephone numbers
134
Building Technologies
Fire Safety & Security Products
Phone D Reporting
P189E 1-8E 1-8E
Option Display text Description
1
Latch Key Report
Report Latchkey Disarm: if the panel is armed in Latchkey Report Mode by using a
Code, Key-switch,
, , or buttons, any code or key-switch without the
Latchkey option (P4E or P122E Option 6 off) used to disarm the Alarm will cause a
Disarm report to be sent via the dialer. Normally the report format for the telephone
number would be set to Domestic or Voice reporting.
2
Delinquent
Report
Report Delinquency Alarm: if the panel has been configured for Delinquency
monitoring (P67E) and an area has not been armed for the time set at P67E, a
Delinquency Alarm will be sent to the Monitoring Station if Contact ID or 4 + 2 is set
as the reporting format.
3
Tests Report
Send Test Calls: if Contact ID or 4 + 2 formats are used for reporting alarm, the panel
can also send Automatic test calls. If this option is turned on the test calls will be sent
but if test calls are not required they can be disabled by turning this option off.
4
Fuse Report
Report Fuse Failure: the panel has two on-board thermal fuses designed to protect
the 12 V DC outputs from short circuits. If this option is on and either of these fuses
are open, a report will be sent to the monitoring station if Contact ID is set as the
reporting format.
5
Output Fail
Report
Report Output 1 or 2 Fail: the panel has two high current outputs (output 1 & 2).
These outputs are normally used to drive sirens or strobes for local alarm warning. If
option 8 at location P37E is on for either output 1 or 2 the output status will be
monitored (e.g. wire to siren has been cut). If this option is on and a fault is detected
on the output, a report will be sent to the monitoring station if Contact ID is set as the
reporting format.
6
Time Change
Report
Time Change Reporting: if this option is turned on all changes in the RTC – real time
clock setting will be reported.
7
Missing Keypad
Report
Missing Keypad Reporting: if this option is turned on and a Keypad is disconnected it
will be reported immediately.
8
RF Blocking
Report
RF interference (Jamming) detection: if the System detects a RF signal which is not
according to the transmission standard of EN 50131 a jamming signal (frequency
blocking) will be reported.