Zones
117
Building Technologies
Fire Safety & Security Products
Zone Confirm Alarm Output
P168E 1-16E 1-8
If the option near alarm zone or confirmed alarm zone is activated (this could be
done only for a total Area. See chapter
17.1: Area arm and special function
options; Zone B Options; P46E 1-2E 1E) this location assigns zones to outputs for
alarms that occur when confirmed alarm zone function is activated (second alarm
has occurred- confirmed alarm happened).
Option 1 = Output 1; Option 2 = Output 2 etc.
20.8 Zone alarms to keyboard buzzer mapping
Zone Arm Beeps
P134E 1-16E 1-8E
If an Area is Armed and a zone assigned to that Area activates, the zone can
sound the buzzer at selected keypads for local alarm signaling. This location
assigns zone alarm beep to a keypad for alarms that occur when in the Full Armed
State.
Option 1 = Keypad 1; Option 2 = Keypad 2 etc.
Zone Stay Beeps
P135E 1-16E 1-8E
If an Area is Stay Mode Armed and a zone assigned to that Area activates, the
zone can sound the buzzer at selected keypads for local alarm signaling. This
location assigns zone alarm beep to a keypad for alarms that occur when in Stay
Mode is armed.
Option 1 = Keypad 1; Option 2 = Keypad 2 etc.
Zone 24Hours Beeps
P136E 1-16E 1-8E
If a zone is programmed as a 24 Hour type and it activates, the zone can sound
the buzzer at selected keypads for local alarm signaling. If the zone is a standard
24 hour type (P123E 3E) or Fire type (P1235E) the keypad buzzer will sound until
reset by a User but if it is an auto-reset type (P123E 4E) the keypad buzzer will
reset when the input clears.
Option 1 = Keypad 1; Option 2 = Keypad 2 etc.
Zone Chime Beeps
P137E 1-16E 1-8E
If a zone is programmed as a Chime zone and it activates, the zone can sound the
buzzer at selected keypads for local alarm signaling. The duration of the Chime
beep is programmed at location P94E. The Chime function can also be locally
disabled at each keypad individually if not required.
Option 1 = Keypad 1; Option 2 = Keypad 2 etc.
Zone Tamper Beeps
P139E 1-16E 1-8E
If a hardwired zone is programmed to allow tamper monitoring (P125E types 12, 13
& 14), or the zone is a radio detector with tamper, the zone tamper can beep the
keypad buzzer at individual keypads.
Option 1 = Keypad 1; Option 2 = Keypad 2 etc.