18.7 Keypad <B> button options
Keypad B Key Areas
P80E 1-8E 1-2E
Option Display text Description
1
Area A
Area A: this option assigns the keypad
button to Area A. If a keypad button is
assigned to only Area A it can only arm or disarm that area.
2
Area B
Area B: this option assigns the keypad
button to Area B. If a keypad button is
assigned to only Area B it can only arm or disarm that area.
Keypad B Key Options
P81E 1-8E 1-8E
Option Display text Description
1
Can Arm
<B> button can arm – This option enables single button arming using the
button.
For single button operation to work options 2 & 3 must be off at location P46E
<B> button can arm Stay Mode – This option enables single button arming of Stay
Mode using the
button. For single button operation to work options 2 & 3 must be
off at location P46E.
2
Can Stay
Following arming of Stay Mode, if the
button is pressed, all entry & exit
delays will be reset to zero for that armed period.
3
Open Anytime
<B> button can disarm at all Times – This option enables single button disarming
using the
button. For single button disarm operation to work options 2 & 3 must be
off at location P46E.
4
Unstay Anytime
<B> button can disarm Stay Mode at all Times – This option enables single button
disarming of Stay Mode using the
button. For single button disarm operation to
work options 2 & 3 must be off at location P46E.
5
Can Reset
Alarms
<B> button can reset Alarms – If this option is on, pressing the
button (provided
Option 3 is also on) will reset an alarm condition without having to enter a user code.
6
Latch Key Open
<B> button can arm Latchkey Mode – This option enables single button arming of the
alarm in Latchkey report mode using the
button. For single button arm operation to
work options 2 & 3 must be off at location P45E. When Latchkey Mode is set on
arming, any code without the Latchkey option (P4E Option 6) used to disarm the
alarm will cause a disarm report to be sent via the dialer.
7
Open on Exit
<B> button can disarm during Exit Delay – This option allows single button disarming
using the
button provided the Armed Mode exit delay is active. If the exit delay has
expired the
button cannot be used to disarm the alarm. For single button disarm
operation to work options 2 & 3 must be off at location P46E
8
Unstay on Exit
<B> button can disarm Stay Mode during Exit Delay – This option allows single button
disarming of Stay Mode using the
button provided the Stay Mode exit delay is
active. If the Stay Mode exit delay has expired the
button cannot be used to disarm
Stay Mode. For single button disarm operation to work options 2 & 3 must be off at
location P46