Other available control codes:
This values are defined in Dialer Æ Voice/CID
Microphone Command Control Code:
The panel can be used to allow remote listen-in via an on-site microphone. This
value is the DTMF code that must be used when turning the microphone on or off.
Pressing the <*> button will toggle the microphone.
Dialer Acknowledge Code:
If the panel is set to report in Domestic or Voice reporting formats, you can simply
kiss-off (acknowledge) the alarm by pressing the <#> button on the remote
telephone. If you want to use a secure kiss-off method, you can program a 1-4 digit
code at this location. If a code is programmed at this location you must enter in the
code followed by the <#> button to kiss-off the alarm event.
Test Message Control Code:
There is a possibility to force a test call from the panel to a monitoring company
using the Contact ID test message by dialing the panel and entering the code
programmed at this location on the telephone.