Telephone numbers
133
Building Technologies
Fire Safety & Security Products
Phone B Reporting
P187E 1-8E 1-8E
Option Display text Description
1
Duress
Report Supervised Duress Alarm: if this option is on the panel will report a Duress
radio Alarm (see chapter
13.2: Duress digit; P25E 2E).
2
Supervised Radio
Fail
Report Supervised Radio Alarm: if this option is on the panel will report a Supervised
radio Alarm (see chapter
13.4: Radio zone supervised timer; P25E 4E).
3
Zone Inactive
Report Zone Inactivity Alarm: if this option is on the panel will report a Zone Inactivity
(Sensor-watch) Alarm (see chapter
20.11: Zone movement / activity control – watch
timer; P163E).
4
Keypad Panic
Report Manual Panic Alarm: if this option is on the panel will report a Keypad
generated Panic Alarm.
5
Keypad Fire
Report Manual Fire Alarm: if this option is on the panel will report a Keypad generated
Fire Alarm.
6
Keypad Medical
Report Manual Medical Alarm: if this option is on the panel will report a Keypad
generated Medical Alarm.
7
Pendant Panic
Report Radio Pendant Panic Alarm: if this option is on the panel will report a Panic
Alarm generated by a radio key (pendant).
8
Bypassed
Report Zone Bypasses: if this option is on the panel will report a Manual or Auto
Bypass on a zone.
Phone C Reporting
P188E 1-8E 1-8E
Option Display text Description
1
All Arm/Open
Report Arm/Disarm: if this option is on then all Arm/Disarm signals will be reported to
a Monitoring Station if Contact ID or 4 + 2 is set as the reporting format.
2
All Stay/Open
Report Stay Mode Arm/Disarm: if this option is on then all Stay Mode Arm/Disarm
signals will be reported to a Monitoring Station if Contact ID or 4 + 2 is set as the
reporting format.
3
Open after Alarm
Send Disarm only after an Alarm: if this option is on, the panel will not normally send
an Arm/Disarm signal to the monitoring company, however, if a zone alarm occurs
then the panel will send a Disarm following the disarming of the panel to show it has
been turned off by a valid user.
4
Unstay after
Alarm
Send Stay Mode Disarm only after an Alarm: if this option is on, the panel will not
normally send a Stay Mode Arm/Disarm signal to the monitoring company, however, if
a zone alarm occurs then the panel will send a Stay Mode Disarm following the
disarming of the panel to show it has been turned off by a valid user.
5
Stay Mode
Alarms
Report Stay Mode Zone Alarms: if this option is on, the panel will report zone alarms
in Stay Mode.
6
Program Entry
Report Access to Program Mode: if this option is on the panel will report a Contact ID
code to indicate that either Client or Installer program Modes have been accessed.
7
24 Hours to
Domestic
Report 24 Hour Alarms for Domestic/Voice Formats: when the panel is set to send
alarms via domestic or voice mode, No alarms will normally be sent for 24 hour
zones. If 24 hour alarms are required to be reported in Domestic/Voice mode then this
option must be turned on.
8
Send Restores
Report Zone Restores: if this option is on the panel will report all zone restores in
Contact ID or 4 + 2 formats. If this option is turned off the panel will only report the
alarms.