23.4 Maximum dial re-tries per telephone number
Phone Retries
P184E 1-8E 0-99E
(Value 0-99)
The maximum dial retries is the number of times that the panel will dial a telephone
number in an attempt to get kissed-off.
23.5 Dial progress options
Phone A Reporting
P186E 1-8E 1-8E
Option Display text Description
1
AC or Fuse Fail
Report Mains Fail: if this option is on the panel will report a Mains fail after the report
delay time (P25E 6E) has expired.
2
Battery Low
Report Battery Low: if this option is on the panel will report a Battery Low.
3
Radio Low
Battery
Report Radio Battery Low: if this option is on the panel will report a Battery Low from
any radio zones that have the battery status monitored.
4
Line Fail
Report Line Fail: if this option is on the panel will report a Telephone Line fail. The
panel will send the line fail and the line restore at the same time.
5
System Tamper
Report System Tamper: if this option is on the panel will report a Tamper Alarm on the
panel tamper input.
6
Keypad Tamper
Report Keypad Tamper: if this option is on the panel will report a Tamper Alarm from
a keypad fitted with a tamper switch or a wrong code alarm from a keypad.
7
Zone Tamper
Report Zone Tamper: if this option is on the panel will report a Zone Tamper Alarm.
8
Radio Tamper
Report Radio Tamper: if this option is on the panel will report a Radio Tamper Alarm.