Zones
112
Building Technologies
Fire Safety & Security Products
20.3 Special zone type options
Zone C Options
P124E 1-16E 1-8E
Option Display text Description
1
Ignore Seal
Can arm if Zone is not Ready: if this option is turned on, plus Options 7 or 8 or on at
P45E (cannot arm if zones not sealed/Ready), this zone can be unsealed and the
panel can still be armed. This option allows the panel to still be armed if a low
security zone is unsealed yet still stopping arming if a high security zone is unsealed
2
Multiple Reports
Will send Multiple Reports to Dialer: if this option is turned on, a zone will send an
alarm report to the monitoring station every time it is activated. If the option is turned
off, the zone can only send one alarm report per armed cycle
3
Activity Monitor
Zone is monitored for Inactivity: if this option is on the zone will be checked to see
that it operates during the disarmed state. If it is not operated within the time set at
P163E a Sensor-watch alarm will be generated. This feature is designed to detect a
faulty zone that is not operating normally or one that has had it’s detection area
blocked. If a detector has this option turned on and it doesn’t operate when disarmed,
the timer at location P163E will start to count down. The timer is stopped when the
area assigned to the zone is armed and resumes with the saved value when
disarmed again. The timer is reset back to the original value every time the zone
operates while disarmed.
4
Soak Test
Zone is a Soak Test Zone: if a zone is suspected of being faulty and is causing false
alarms, you can turn it into a Soak Test Zone and it will still be monitored for alarms
when armed but it will not cause the sirens to sound or report to the dialer. The Soak
Test zone will still be logged in the event memory however so it is possible to check
the activity of the zone, via the memory, and after a suitable period of no alarms it
can be re-instated as part of the alarm by removing the Soak Test option.
5
Report to
Area B
Zone will report to Area B Account Code: if a zone is in Areas A & B and it goes into
alarm, it will default to reporting on the Area A Account Code (see chapter
17.5:
Monitoring account code number; Area Account Code; P62E). By turning this option
on when a zone is in both areas it will report to Area B account Code
6
No 24 Hours
Report to dialer
Zone will not report 24 Hour Alarms via Dialer: if this option is turned on and the zone
is set as a 24 Hour type, when an alarm is generated, the alarm will not be
transmitted to the monitoring station via the dialer.
7
Acknowledge
Pulse
Pulse output on Kiss off after Alarm: this option activates the output function pulse
output on kiss off after a zone alarm for a defined pulse time.
8
Exit Terminator
Exit Terminator: using this option will stop the area exit delay time by closing this
input and arm the area immediately with 3 seconds delay.