Dialer
126
Building Technologies
Fire Safety & Security Products
22.4 Listen dialing function through keypad and output
Keypad Listen In
P175E 6E 1-8E
The panel provides the facilities to use the buzzer in the keypad as a speaker to
listen to the call being made by the dialer. To use this feature a 5
th
wire must be
connected between the panel and a keypad using the listen-in terminals. The
options above allow many combinations of the listen-in to be used or it can be
disabled by selecting no options.
Option Display text Description
1
Dial when Open
Listen-in enabled when dialing only and in disarmed State
2
Dial when Closed
Listen-in enabled when dialing only and in armed State
3
Dial when Stay
Listen-in enabled when dialing only and in Monitor Mode
4
Full Call Open
Listen-in enabled through the entire call only in disarmed state
5
Full Call Closed
Listen-in enabled through the entire call only in armed State
6
Full Call Stay
Listen-in enabled through the entire call only in Monitor Mode
7
Answering a call
Listen-in enabled when the panel answers a call
8
At all times
Listen-in on at all times
Output 1 Listen In
P175E 7E 1-8E
The panel provides the facilities to use a speaker connected to Output # 1 to listen
to the call being made by the dialer. For this to happen the device connected to
Output # 1 must be an 8Ώ horn speaker. The options above allow many
combinations of the listen-in to be used or it can be disabled by selecting no
options.
Option Display text Description
1
Dial when Open
Listen-in enabled when dialing only and in disarmed State
2
Dial when Closed
Listen-in enabled when dialing only and in armed State
3
Dial when Stay
Listen-in enabled when dialing only and in Monitor Mode
4
Full Call Open
Listen-in enabled through the entire call only in disarmed state
5
Full Call Closed
Listen-in enabled through the entire call only in armed State
6
Full Call Stay
Listen-in enabled through the entire call only in Monitor Mode
7
Answering a call
Listen-in enabled when the panel answers a call
8
At all times
Listen-in on at all times