Contact less card reader IAR6-30 for keypad bus connection
30
Building Technologies
Fire Safety & Security Products
5 Contact less card reader IAR6-30 for keypad bus
connection
The IAR6-30 contact less reader is used as a proximity access card reader with a
full numeric keypad for additional PIN functionality and standard tags or cards
which operates in the 125 kHz band. Its functionality is identical to a keypad and
therefore it is programmed into the system as a standard keypad.
In total maximum 8 keypads/card readers can be connected to a Sintony 60 control panel (Sintony 60
compact has one build in already- e.g. 7 more).
Under the following limitations:
Bus connections- max. length*
Up to 25 meter, 22AWG,
wire diameter 0.6mm
7 Keypads IKP6-03 or
Reader IAR6-30
8 Keypads IKP6-03 or
Reader IAR6-30
Up to 100 meter, 20AWG,
wire diameter 0.8mm
4 Keypads IKP6-03 or
Reader IAR6-30
4 Keypads IKP6-03 or
Reader IAR6-30
Each reader must have a unique keypad address number from 1-8 assigned so
that the various program options can be assigned (see chapter
18.13: Learn a card
reader to the system, addressing an LED; Reader Learn ;P99E).
The proximity readers flash out the assigned keypad address number on the LED whenever the panel
is in Installer Program Mode. This allows quick identification of the assigned address for each reader.
5.1 Additional arming functions
Depending on program options the reader IAR6-30 could also be used as an
arming/disarming device. If a user code or tag is presented to the reader it could
directly Arm/Disarm the alarm system. The reader can be set-up to operate on:
z a proximity tag or card only
z on entering of a valid user code only
z on presentation of the tag/card followed by the user code (PIN).
If the presented tag requires a PIN number to be entered, the LED on the reader
will flash for 5 seconds after a valid tag to indicate that the PIN number should now
be entered.
5.2 Panic functions
If the two button <Panic> ( ), <Fire> ( ) or <Medical> ( ) functions are
programmed to the keypad/reader (see chapter
18.2: Keypad button individual
operations (beeps and LED control); Keypad Options; options 5, 6 & 7; P72E)
these manual alarms can be generated at the reader by pressing
& for
Panic,
& for Fire and & for Medical alarms.