P175E 2E 1-8E
Option Display text Description
1
Cycle Phone #s
Step to next Number: if more than one telephone number is programmed, this option
will force the dialer to step through each number after a call. If this option is off the
dialer will make all calls to the first number before moving on to the next number.
2
Allow Callback
Upload/download uses Call-back Number: a Telephone number can be programmed
as a Call-back number. If this option is turned on, and a PC contacts the panel a
direct connection cannot be made with the PC. The panel will hang-up the call and
dial the PC back on the Call-back number.
3
PC only if Open
Upload/download only if Disarmed: if this option is turned on, and a PC attempts to
contact the panel while the alarm is Armed a direct connection cannot be made as
the panel will not answer the call. If the panel is Disarmed a connection can be
established.
4
Tests if armed
Send Test Calls Only if Armed: if this option is On the panel will only send a daily test
call if it is Armed. This option assumes that the normal arm/disarm signals sent on a
daily basis can serve as a test and that the connection only needs to be verified daily
if the panel is left in the armed state for periods longer than 24 hours.
5
P175E 5E as
Days
Test Time period is in days: if this option is activated the timing which is programmed
at P175E 5E 0-255E for the time interval for the next test call can be changed from
hours to days. E.g. instead of 24 hours this than means 24 days- for the test call
period. This option is not recommended. For safety reasons a test call should be
done at least every 24 hours.
6
Hold for DTMF
Hold line open following Domestic/Voice report for DTMF control: if this option is On
the dialer will keep the telephone line open after being kissed-off following a
Domestic or Voice alarm call so that the person at the phone can then use their
DTMF codes to arm/disarm the system or turn on the optional microphone if required.
7
1st-Open/
Last-Close
First to Open Last to Close Reporting: if this option is on and the alarm is split into
two Areas, then the Arm report to the monitoring station will only be sent when both
areas are armed and it will be a single report on Area A account code (last to close).
On Disarming of the alarm the disarm report will be sent when either Area is
disarmed (first to open). Only one disarm report will be sent using the Area A account
code. If zones in both areas are bypassed, the bypass report for all zones will only be
sent when both areas are armed (last to close) but the Bypass restore reports will be
sent only when the Area associated with the zone is disarmed. In this way if an area
remains armed and it’s associated bypassed zone/s are still bypassed the monitoring
station knows that the bypasses have not been removed yet.
-
Up to version 9.07: Spare
8
Alarm Enables
Answer
Valid as of version 9.07:
Answer after 1 ring for Two Way Voice Call-back Mode (if using speech protocol): if
this option is turned ON and a full duplex voice board is fitted, the panel will answer
an in-coming call after 1 ring and automatically enter full duplex two way voice mode
if an alarm was already transmitted.