Programming users
67
Building Technologies
Fire Safety & Security Products
11.5 Radio user type
Only Users 21-100 can be Radio Users.
Pendant Type
P7E 21-100E 1E
Option Display text Description
0 Free Not in Use
1 IRCW6 SiWay Type: if a SiWay Radio Pendant is being used (IRCW6) set the type to 1.
When the pendant detects a battery low it will send a signal to the panel.
2 Free Not in Use
11.6 Radio user privileges
Only Users 21-100 can be Radio Users.
Pendant Options
P8E 21-100E 1-5E
Option Display text Description
1 Can Open
Always
Pendant can disarm at All Times: if a Radio Pendant has option 1 on, they can disarm
the alarm at any time. If this option is off, the pendant cannot disarm if the panel is in
alarm state.
2 Immediate Panic Pendant will cause an immediate Panic Alarm: if a Radio Pendant has option 2 on, a
Panic Alarm will be generated immediately the button is pressed.
3 Delayed Panic Pendant will cause a delayed Panic Alarm: if a Radio Pendant has option 3 on, a
Panic Alarm will be generated if the button is pressed for longer than 1.5 seconds. If
the button is released before the time expires, no Panic Alarm will be generated.
4 Disarm on Entry Pendant only works during entry delay: a Radio Pendant can only disarm the area
during the entry delay time, this means, it is strictly required to activate the entry root,
before the user can disarm the area.
5 Duress on Open User is a Duress Code User: this option for a Radio Pendant if it should be used as a
dedicated Duress code. All user options will be executed, but an additional pendant
panic alarm will be generated.
6 Spare
7 Spare
8 Spare