Extension modules for Sintony 60 control panel
42
Building Technologies
Fire Safety & Security Products
7 Extension modules for Sintony 60 control panel
Various extension units could be connected to the Sintony 60 to expand the
functionality.
7.1 Output module 12V/1A IRO6-04 (Output 5-8)
With this extension PCB the Sintony 60 could be extended with additional 4 Relays
to a maximum of 8 Outputs. Each relay could switch a max. power of 12V/1A.
The connection to the Sintony 60 control panel is realized over the system bus.
Therefore it is an intelligent member of the Bus and could be programmed over the
control panel. It could be installed either directly in the control panel (Sintony 60M-
modular only) or external. The terminals are connected to corresponding terminals
on the remote devices marked POS, NEG, CLOCK, & DATA.
Max. 2 boards can be connected (max. 8 outputs total).
7.2 Zone expander module IZE6-04
This Module makes zone doubling and EOL end of line resistor connections very
easy. It contains all necessary resistors to expand the control panel and offers
clearly marked terminal blocks for 2 line in and 4 lines out. This module can be
used instead of the in the delivering included separate resistors and to save
installation costs if placed outside the control unit. (less cabling needed) Maximum
4 expander modules could be used per control panel.
7.3 Radio receiver IRFW6
The IC60 panel can have wireless capability via the IRFW6 receiver module
(Sintony 60 modular optional, Sintony 60 compact already build in).
The receiver will add wireless capability to your system in the form of wireless
Alarm sensors and wireless Remote controls. The IRFW6 connects to the system
bus port as the keypads and the other intelligent bus participants of the system.
The IRFW6 is available in 2 frequencies, 868MHz and 915MHz. Up to 2 IRFW6
can be connected to the panel to increase the coverage range if desired. The red
LED fitted to the IRFW6 receiver will flash at 1 second intervals when in Learn
Mode (see chapter
12.1: Learn a remote control / radio pendant; Pendant learn;
P18E &
20.12: Learn a wireless detector / code to the system; Zone Learn Radio;
P164E). The LED will also turn on when it is receiving an actual radio transmission
(on steady). It could be installed either directly in the control panel (Sintony 60M-
modular only) or external. The terminals are connected to corresponding terminals
on the remote devices marked POS, NEG, CLOCK, & DATA. In the Sintony 60
compact is the radio receiver normally already integrated (could vary in different
countries), but a second receiver IRFW6 can also be connected externally through
the bus to increase the coverage range if desired.
Comentarios a estos manuales