Keypads
97
Building Technologies
Fire Safety & Security Products
18 Keypads
18.1 Keypad area assignment
Keypad Areas
P71E 1-8E 1-2E
z Option 1 Area A: this option assigns Area A to keypads. If a keypad is assigned
to only Area A it can only arm or disarm that area.
z Option 2 Area B: this option assigns Area B to keypads. If a keypad is assigned
to only Area B it can only arm or disarm that area.
There are more options to choose but the System supports only 2 Areas (1-2)
18.2 Keypad button individual operations (beeps and LED control)
Keypad Options
P72E 1-8E 1-8E
Option Display text Description
1
Enable Chime
key
<Chime>: this option enables the
button on the LCD keypads. Chime alarms to the
keypad buzzer and outputs are disabled when
is off. If a zone is programmed as a
Chime Zone, it can beep the buzzer on a keypad and/or turn on an output as well to
give a local Chime Mode indication. A typical use of Chime Mode is as a door minder
in a shop. Sometimes it may be desirable to disable Chime Mode without the need to
reprogram the panel. This can be achieved by allowing Chime Mode to be disabled
with the
button. If you press the button on a LCD keypad for 2 seconds (and
this option is turned on for that keypad) the display will show Chime Mode OFF. This
means that the buzzer will now not sound at the keypad concerned and any Chime
Mode outputs will not activate. Performing the process again will toggle chime mode
back to the on state again.
2
Bypass
<Bypass> button Enabled: this option enables the
button (by keypad number) on
any keypads connected to the pane
3
Panic
<Panic> button Enabled: this option enables the button (by keypad number) on the
Keypad connected to the panel
4
Delayed Panic
Delayed Operation of <Panic> button: this option assigns a 2 second delay before the
button will cause an alarm. The button must be held down for longer than 2
seconds to create a panic alarm.
5
1
st
Combination
1 & 3 Panic Alarm Enabled: this option enables a Panic Alarm to be created when
buttons
& are pressed simultaneously on the reader or keypad. It also enables
the
&
C
tr
l
Panic Alarm when both buttons are pressing simultaneously on the LCD
keypad.
6
2
nd
Combination
4 & 6 Fire Alarm Enabled: this option enables a Fire Alarm to be created when
buttons
& are pressed simultaneously on the reader or keypad. It also enables
the
& Fire Alarm when both buttons are pressing simultaneously on the LCD
keypad.