Siemens IC60 Manual de usuario Pagina 41

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 172
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 40
Voice board IAV6-90
41
Building Technologies
Fire Safety & Security Products
6.3.4 DTMF code table
The following DTMF codes are used for sending responses and operating
commands.
Command Default Description
P175E 12E 2 Sets the DTMF code for use by the CMS to operate the
OUTPUT (1-4 digits).
P175E 13E 1 Sets the DTMF code for turning the microphone ON/OFF.
P175E 14E # Dialer acknowledge DTMF code
P175E 15E 99 Forces a test call for testing the DTMF response codes
(AREA A/B).
P63E 1-2E Sets the DTMF code for ARM and DISARM.
Tab. 2 List of DTMF codes
6.4 Mute siren
Valid as of version 9.07:
This option must be programmed to mute all acoustic devices automatically during
listen-in with the full duplex two way voice board.
According EN 50131-3 if an alarm occurred during Exit Delay the dialer should
reported only after 30sec.
Only output 1 and the keypad buzzers are automatically muted. If an external siren is connected to
another output this will not work.
6.5 Domestic kiss-off / Auto kiss-off
Domestic Kissoff
183E 6E
Auto Kiss-off for Voice/Domestic reporting: if Voice or Domestic Report Format is
used and this option is turned On, the alarm will be reported and it can be kissed
off by entering the kiss-off code (P175E 14E) at the telephone but if not kissed off
the event is automatically removed from the dialer buffer once the maximum dial
re-tries has been reached for the telephone number. A new event must then be
created before the dialer will dial again.
We recommend using this function if a customer does not want to acknowledge alarm messages
manually.
Please note: the dialler stops after the first alarm message.