Miscellaneous installer and panel options
79
Building Technologies
Fire Safety & Security Products
14.2 Miscellaneous installer options
Installer Options
P25E 11E 1-8E
Option Display text Description
1 Installer Alarm
Reset
Entry to Installer Mode Resets Confirmed Alarms: if this option is turned on and a
confirmed alarm has occurred, the alarm cannot be re-armed until the Installer has
reset the alarm. The Installer must access Installer Program Mode via Client Mode to
reset the system. The zones that caused the alarm will latch on (even when
disarmed) until reset by the installer to indicate that lockout is in effect.
2 Installer Tamper
Reset
Entry to Installer Mode Resets Tamper Alarms: if this option is turned on and a
Tamper alarm has occurred (system or zone tampers), the alarm cannot be re-armed
until the Installer has reset the alarm. The Installer must access Installer Program
Mode via Client Mode to reset the system. The trouble indication will latch on (even if
the tamper alarm has been cleared) until reset by the installer to indicate that lockout
is in effect.
3 Installer Battery
Reset
Entry to Installer Mode Resets Battery Alarms: if this option is turned on and a Battery
alarm has occurred (system or zone tampers), the alarm cannot be re-armed until the
Installer has reset the alarm. The Installer must access Installer Program Mode via
Client Mode to reset the system. The trouble indication will latch on (even if the
tamper alarm has been cleared) until reset by the installer to indicate that lockout is in
effect.
4 Installer Supv.
Reset
Entry to Installer Mode Resets Supervision Alarms: if this option is turned on and a
Supervision alarm has occurred (system or zone tampers), the alarm cannot be re-
armed until the Installer has reset the alarm. The Installer must access Installer
Program Mode via Client Mode to reset the system. The trouble indication will latch
on (even if the tamper alarm has been cleared) until reset by the installer to indicate
that lockout is in effect.
5 No Arm Missing
Keypad
Cannot Arm if there is a keypad Fault: if this option is turned on and a missing keypad
alarm is present the panel cannot be armed until the keypad has been re-instated.
6 No Arm Bad
Comms.
Cannot Arm if there is a Telephone Line Failure or Comms Fault: if this option is
turned on and the control panel has detected a telephone line fault or the dialer failed
to get kissed off (Comms Fault) following an alarm report the panel cannot be armed.
To reset the line failure the telephone line must be re-instated to allow arming again.
To reset the Comms Fault alarm, a user must access the memory.
7 Bad Code
Lockout
10 Incorrect Code Attempts locks out the keypad for 90 Seconds: if this option is
turned off the panel will create a keypad tamper alarm if more than 4 incorrect codes
are entered at a keypad but the keypad will not be locked out. If this option is turned
on the panel will create a keypad tamper alarm if more than 10 incorrect codes are
entered at a keypad and that keypad will then be locked out for 90 seconds.
8 Min. 4 Digit Code User Codes Must be 4-6 Digits: if this option is turned on, all User Codes must be
between 4-6 digits long. If it is turned off, the User Codes can be 1-6 digits long