Option Display text Description
7
3
rd
Combination
7 & 9 Medical Alarm Enabled: this option enables a Medical Alarm to be created when
buttons
& are pressed simultaneously on the reader or keypad. It also enables
the
& Medical Alarm when both buttons are pressing simultaneously on the
LCD keypad.
8
Stay Arming
Beep
Stay Armed Beep to Keypad: If this option is turned on the keypad will give three
short beeps when Stay Mode is armed. It is designed to be used when stay mode exit
delay beeps (P59E) are turned off to provide an audible indication that. Stay mode is
now armed from the selected keypad
18.3 Keypad system beeps and LED options
Keypad Beeps
P73E 1-8E 1-8E
Option Display text Description
1
AC Fail
Mains Fail Beeps Keypad Buzzer: if this option is on a Mains Failure will cause the
keypad buzzer to sound continuously. The continuous beep will automatically clear
when the Mains returns to normal or it can be silenced by pressing the
button on
the keypad.
2
Fuse Fail
Fuse Fail Beeps Keypad Buzzer: if this option is on a Fuse Failure (12 V DC output
short) will cause the keypad buzzer to sound continuously. The continuous beep will
automatically clear when the short is removed and the fuse returns to normal or it can
be silenced by pressing the
button on the keypad.
3
Battery Low
Battery Low Beeps Keypad Buzzer: if this option is on a Panel Battery Low will cause
the keypad buzzer to sound continuously. The continuous beep will automatically
clear when the battery returns to normal or it can be silenced by pressing the
button on the keypad.
4
Line Fail
Telephone Line Fail Beeps Keypad Buzzer: if this option is on a Telephone Line
Failure will cause the keypad buzzer to sound continuously. The continuous beep will
automatically clear when the Telephone Line returns to normal or it can be silenced
by pressing the
button on the keypad.
5
System Tamper
System Tamper Beeps Keypad Buzzer: if this option is on a Panel Tamper Alarm will
cause the keypad buzzer to sound continuously. The Alarm must then be cleared by
entering in a valid code at the keypad.
6
Receiver Fail
Receiver Fail Beeps Keypad Buzzer: if this option is on a Receiver Failure will cause
the keypad buzzer to sound continuously. The continuous beep will automatically
clear when the Receiver starts to see transmissions again or it can be silenced by
pressing the
button on the keypad.
7
Leds off Armed /
Power safe
Turn Off Keypad LEDs when Armed: if option 7 is activated the backlight of LCD and
all LEDs are turned off after 10 sec. when the panel is not in use. By pressing any
button lights will go on again.
8
AC Fail dims
Keypad
Turn Off Keypad LCD & Keypad Backlighting on Mains Fail: this option allows the
backlighting on an LCD on a keypad (both the keypad buttons and the LCD module
backlighting) to be turned off when there is a Mains Failure. It is normally used to cut
the power consumed by the keypad during a power failure. The LCD backlighting will
turn off within 90 seconds of the mains failing. If a button is pressed at the keypad the
backlighting will turn back on again. Following 90 seconds of no keypad activity the
backlighting will turn off. The LCD backlighting will return to the normal state when
Mains is restored.