LCD keypad
44
Building Technologies
Fire Safety & Security Products
8.2.1 LCD keypad Installation
Bus connection
The connection to the Sintony 60 control panel is realized over the system bus. It is
an intelligent member of the Bus with a unique Bus address (refer to Keypad Set
up). It could be installed external to the Sintony 60 Control Panel (modular and
compact version). The terminals are connected with a 4 wire cable to the
corresponding terminals on the Control Panel marked POS, NEG, CLOCK, &
DATA.
The 5
th
bus wire- Listen dialing function
The 5th wire is an optional Listen-dialing connection. It is connected from the LIN
terminal of the keypad to the Lin terminal of the panel keypad port. With the Listen-
in wire connected the user is able to hear the call progress during dialing at the
keypad (only if the program options at address P175E 6E are turned on).
Maximum cable length
The maximum recommended cable using standard 0.6mm security cable is 25m.
Cable runs exceeding this distance may require 0.8mm cable. Always use good
quality cable. Some installations may require CAT5 data cable to ensure data
integrity in noisy sites.
Keypad Tamper Switch
The LCD keypad has a tamper switch at the back side. Make sure that when the
Keypad is installed the Tamper contact is closed by the pressure of the wall. If the
switch needs some adjustment, the tamper contact could be fitted with an
additional distance screw to ensure proper contact to the wall and therefore a good
protection of the housing against manipulation.
Activation- programming - addressing
A LCD Keypad has to be learned to the system. To start after installations with the
first steps please refer to the chapter
8.4: Programming a keypad to the system –
addressing. This contains:
z Change language
z Address the keypad to the system bus
z Copy text files into the new Keypad
8.3 Programming a LCD keypad – Local program mode
The Keypad can be programmed locally via the Keypad buttons or by a PC with
the separate available programming cable IAQ6-1 and the programming Software
Sylcom 60 IAS6-1 through the programming interface port on the back side of the
Keypad. (It could also be programmed remotely through the programming port of
the control panel unit if connected to the bus).
In the local program Mode object related names like Zones, Users, Outputs etc.
can be programmed. System settings have to be programmed in the Installer
Program Mode (see chapter
9.4.1: Access to installer program mode).