What can the installer do when the user forgets its user code?
Answer: when the user forget his user code there are several things that the
installer can do:
A - If the system is disarmed and direct access to installer mode is enabled then
get into installer mode and check the code
B - If the system is armed you can use the upload/download software and then
disarm, get the code and if needed change it.
C- If the system is armed there is a second possibility, in the default configuration
the key-switch is enabled, so you can simulate a key-switch by adding a 4.7K ohm
resistor to the tamper input. This way you can disarm the system
D - Another way to reach installer mode is the “back door “option. If the installer
enabled the back door option then you have to open the tamper, power up the
system with a tamper opened and press
Prog
than and the system enters installer
mode
What is wrong when an installer connects to the control panel with the
upload/download software and there communication (there is a connection,
the Rx TX led's are Blinking) but you can upload or download or enter real
time monitor?
Answer: this can happen if there is a security code defined in the system the code
isn’t typed when you are connected, all you have to do is type the code.
If the installers replace the receiver board is there a need to learn the
detectors again?
Answer: No, when you learn the detectors the radio code is saved in the control
panel memory, and not in the receiver
Is it possible to connect a second receiver to the control panel in case of bad
reception areas, and if yes wont there be a double alarm (one from each
receiver)?
Answer: There is no problem to connect several receiver boards, for the control
panel it is the same if it has 1 or 2 or 5 receivers on the bus. There will not be a
multiple alarm from several receivers because there is a short lockout for the
message from the receiver and the panel will only relate to the first one.