Zones
115
Building Technologies
Fire Safety & Security Products
20.6 Supervising setting of wireless detector type
The wireless detectors of this systems work on a transmission protocol which is
called SiWay. This is a 24bit coded transmission signal which gives every detector
a unique number and transmits the special functions such as battery low signals,
tamper alarms, reed switch open/close signals and supervision signals.
This information is sent by every detector randomly between 5-7 minutes.
To monitor if all detectors are still available in the system, the control panel is using
the supervision signal of the detector. If this option is turned on the supervise timer
is constantly being reset while valid supervisory signals are being received from
the detector. If no supervise signals are received from the PIR within the supervise
timer value a supervised alarm is generated. About how to set the supervision
timer refer to chapter
13.4: Radio zone supervised timer (P25E 4E 0-9999E).
Zone Radio Type
P127E 1-16E 3-4E
Option Display text Discription Grade of
Securiy
3 SiWay
Supervised
SiWay with checksum supervised:
selecting this option also starts the
supervise timer (P25E 4E).
High-
recommended
4 SiWay
UnSupervised
SiWay with checksum not-supervised: the
automatic supervisory signal sent by the
detector is ignored in this mode by the
control panel.
Low
To activate this function and connect a wireless detector, the zone must be programmed as a Radio
zone (see chapter
20.2: Zone type options- basic information; P122E 1-16E 5E)
Also the supervision timer must be set (P25E 4E). It is not recommended to use a very short period-
(minimum=1 signal cycle ~ 8 minutes) because it could lead to a high rate of false alarms.