22.7 Forced test call code options
DTMF Call Code
P175E 15E 0-9999E
(Value 1-4 digit code 0-9999)
If a user wishes to remotely force a test call from the panel to a monitoring
company using the Contact ID test message, you can dial the panel and when it
answers enter the code programmed at this location on the telephone.
If a voice board is fitted you can assign a voice message (see chapter
22.8:
Manual test call initiated voice message number; P176E 11E) to indicate that the
function was started. If no voice board is fitted but there is a DTMF IC fitted to the
panel you will get 3 short beeps after the code is entered to indicate the function
was started. Once you hang-up the phone the panel will then make a call to the
monitoring company and send a manual test call message. If no code is
programmed at this location (e.g. 0) the function will be disabled. The code can be
a 1-4 digit number as required.
It is also possible to force a locally generated test call from the panel keypad by
pressing and holding the
C
tr
l
button then within two seconds of pressing control.
This will force a test call to the monitoring company.
If using this remote test code and any of the other remote DTMF codes at locations (P63E,
P175E 12E, P175E 13E & P175E 14E) you should make this code a 4 digit code to ensure the panel
knows what function is being operated. If no other DTMF remote functions are being used this code
can be a single digit.
22.8 Manual test call initiated voice message number
Remote Test Message
P176E 11E
You can trigger the panel by manual (
C
tr
l
+ ) to send test call to the central station
and receive immediately a call (P176E 11E) with your voice recorded indicate that
manual test as been done.