19.3 Key-switch arm-disarm options
Keyswitch Access
P112E 1-2E 1-8E
(1 = Key-switch # 1; 2 = Key-switch # 2)
Option Display text Description
1
Can Arm
Key-Switch can arm: this option enables arming of the assigned Area via the Key-
switch.
2
Can Stay
Key-Switch can arm Stay Mode: this option enables Stay Mode arming of the
assigned Area via the Key-switch.
3
Can Open
Key-Switch can disarm: this option enables disarming of the assigned Area via the
Key-switch.
4
Can Unstay
Key-Switch can disarm Stay Mode: this option enables Stay Mode disarming of the
assigned Area via the Key-switch.
5
Guard Mode
Key-Switch has Security Guard Options: if the key-switch has option 5 on, they can
arm all Areas assigned, but they may only disarm if the panel is currently Armed and
in the alarm state.
6
Latch Key Open
Key-Switch will arm Latchkey Mode: if the panel is armed by a key-switch with this
option on, then the panel will be armed in Latchkey mode. This means that when the
alarm is disarmed by a key-switch with this option off, or a code with option 6 at P4E
off, then a disarm report will be sent. The option is designed to alert the alarm owner
when children have returned home and disarmed the alarm.
7
N/O switch
Key-Switch is N/O (Normally Open): the key-switch can be a N/O (Normally Open) or
a N/C (Normally Closed) key-switch. The normal, or rest state, of the key-switch can
be programmed at this location. If the key-switch contacts usually rest in the open
state and close when the key-switch is operated you should turn on option 7.
8
Momentary
Key-Switch is momentary: the operation of the key-switch can be momentary or
latching. If option 8 is on, the key-switch operation is assumed to be momentary. This
means that each time the key-switch is operated then released the area will toggle its
current state (I.e. if armed it will become disarmed or vice versa). If this option is
turned off it is assumed that the key-switch is a latching type. This means that when
the key-switch is operated and the key removed the contacts remain in the same
state. When a latching key-switch is used, turning on the switch will arm the area and
turning it off will disarm the area.