Voice board IAV6-90
35
Building Technologies
Fire Safety & Security Products
Command control messages for output control on/off and area arm/disarm will need two voice
messages to be assigned. (One for ON confirmation and one for OFF confirmation.) These messages
need to be in direct sequence.
Use Table 1 below to assign each event address to the appropriate voice message
in accordance with the list you have made.
Each event can be assigned a message number from 0-99. When set to "0" the
message will be disabled.
Address Description Message Type Value
(message no.)
P42E 1-8E Outputs Command control 0
P64E 1-2E Areas A&B Command control 0
P160E 1-16E Zone alarm Alarm 0
P176E 1E Keypad or radio panic alarm Alarm 0
P176E 2E Fire alarm Alarm 0
P176E 3E Medical alarm Alarm 0
P176E 4E Mains failure Alarm 0
P176E 5E Mains restored Alarm 0
P176E 6E Battery low Alarm 0
P176E 7E Battery restored Alarm 0
P176E 8E Tamper Alarm 0
P176E 9E Duress alarm Alarm 0
P176E 10E Latchkey disarm Alarm 0
P176E 11E Manual test initiated Command control 0
Tab. 1 List of message addresses
For Output command control and area command control assign the first message number, e.g.
P42E 1E 1 assigns messages 1 and 2 to output 1 (confirming ON and OFF respectively).