14
Engineer programming via the keypad
X-BUS
90
Siemens AB
A6V10276959
Security Products
18.11.2011
1
For readers with a green and a red LED.
2
For SIEMENS readers with a yellow LED (AR618X).
3
Profile 3 is used with HID readers that send a PIN to the panel as a card reading
with a predefined site code (0 )
4
Profile 4 is used with HID readers that send a PIN to the panel as a card reading
with a predefined site code (255 ).
See also
Door Controller [➙ 39]
14.5.4 ADRESSING MODE
X-BUS addressing can be configured in one of the 2 following ways:
Automatic addressing
Automatic addressing can be done with a combination of rotary switch and without
rotary switch expanders. With automatic addressing, the controller over-rides rotary
switches and automatically assigns expanders and keypads in the system unique
IDs in sequential order
Manual addressing
Manual addressing allows manual determination of each expander/keypad ID in a
system. All devices should be installed where required and each ID set manually
using the rotary switches.
If 2 devices of a kind (e.g. expanders) are set to same ID, upon configuration,
both expanders beep and the flashing LED indicates conflict. Reset the switches
and the system rescans.
On a device, if both rotary switches are set to zero (0, 0), the full configuration
becomes an automatic addressing configuration.
To select the ADDRESS MODE:
1. Scroll to ADDRESS MODE.
2. Press SELECT.
3. Toggle for appropriate address mode: AUTOMATIC or MANUAL
4. Press SELECT to update the setting.
14.5.5 XBUS TYPE
To program the X-BUS type from the keypad:
1. Scroll to XBUS TYPE.
2. Press SELECT.