Engineer programming via the browser
Configuring zones, doors and areas
15.8.3 Editing a door
1. Select Settings > System > Doors.
2. Click the Edit button.
3. Configure the fields as described in the table below.
Door inputs
Each door has 2 inputs with predefined functionality. These two inputs, the door
position sensor and the door release switch can be configured.
The door position sensor input can be used for the intrusion part as well. If
the door position sensor input is used also for the intrusion part, the zone
number it is assigned to has to be selected. If the door position sensor is
used only for the access part, the option “UNASSIGNED” has to be
selected.
If the door position sensor is assigned to an intrusion zone, it can be
configured like a normal zone but only with limited functionality (e.g. not all
zone types are selectable).
If an area or the system is set with the card reader, the door position
sensor input has to be assigned to a zone number and to the area or the
system which have to be set.
Description of the zone the door position sensor is assigned to.
Zone type of the zone the door position sensor is assigned to (not all
zones types are available).
The attributes for the zone the door position sensor is assigned to can be
modified.
The area the zone and the card reader are assigned to. (If the card reader
is used for setting & unsetting, this area will be set / unset).
The resistor used with the door position sensor. Choose the used resistor
value / combination.
Select if the door release switch is to be a normally open or normally
closed input.
The resistor used with the door release switch. Choose the used resistor
value / combination.
Select if the door release switch is a normally open input or not.