15
Engineer programming via the browser
Configuring communications
222
Siemens AB
A6V10276959
Security Products
18.11.2011
DNS Server
Enter the IP address of the DNS server.
15.12.4 Registering to SPC portal
The SPC Portal provides you with the ability to remotely connect via the internet to
the embedded web server on the SPC controller without needing to know the WAN
IP address of the SPC unit. The SPC portal server is an external server with a fixed
IP address that has the ability to listen or 'scan' for S PC controllers on specified
port numbers. The default port number that the Portal server listens on is 80 and
the default WAN port (the port address of the SPC as seen from the external
network) is 443.
1. Select Settings > Comms. > Portal.
The following window will be displayed.
2. Configure the fields as described in the table below.
Enabled
Tick this box to enable the Portal Operation.
Portal Port
Enter the Port number that the Portal server is 'listening' on (default: 80).
Portal IP Address
Enter the Fixed IP address of the SPC Portal Service (87.192.253.140 - contact
Siemens for confirmation of this information). The IP address of the Portal server
can also be specified as a DNS name instead of numeric IP format. Note this
requires a DNS server to be configured under Ethernet settings.
WAN IP address
If your ISP has assigned a fixed IP address for your internet connection then
enter it here. If you do not have a fixed IP address then this should be left blank.
WAN Port
Leave this number at the default setting (443) unless instructed to do otherwise
by your network manager.