Engineer programming via the browser
15
Configuring communications
209
Siemens AB
A6V10276959
Security Products
18.11.2011
WPA.
Test
Tick the Test box if a periodic WPA test is required. The timeframe for
periodic testing is configured on the Changing wireless settings [➙ 205]
page.
Button Assignment
Use this section to assign functions to button combinations. Available
functions are Panic, Holdup, Suspicion or RF User Output. More than one
combination can be selected for the same function.
The screen above shows the defaults for the panel for a Financial
installation:
Yellow - Suspicion
Red + Green - Holdup
For Commercial or Domestic installations, the default is:
Red + Green - Panic
Note: If no function is assigned to a button combination, it is still possible to
use that combination by using a trigger. See Triggers [239]
Click on the Save button to save the settings.
See also
Changing wireless settings [205]
Changing wireless settings [➙ 205]
Triggers [ 239]
15.11.3.2 Editing a WPA
To edit a WPA, click the Edit button in the main WPA Configuration and Status
page.
The Edit page is similar to the Add page except that it does not contain the Learn
button for automatically entering the WPA ID.
15.12 Configuring communications
15.12.1 Serial ports
The SPC controller provides 2 serial ports (RS232) that offer the following
functionality:
X10: Serial port 1 is a dedicated interface that supports the X10 protocol. This
protocol allows for use of the existing power cables of a building to transport
control information to X10 devices providing the ability to trigger and monitor
these devices via the SPC Controller programming interface.
Logging of Events: The Serial port 2 interface provides the ability to connect to
a serial port on a PC or a printer. With this connection, a terminal program can
be configured to receive a log of System Events or Access Events from the
SPC controller.
System Information: Serial port 2 also provides an interface via a terminal
program that allows for the execution of a set of commands to interrogate the
controller for specific system information. This facility is available only as a tool
for debug and information purposes and should only be used by experienced
installers.