Engineer programming via the browser
15
Configuring zones, doors and areas
181
Siemens AB
A6V10276959
Security Products
18.11.2011
group is open, including the open door itself.
This output could be connected, for example, to a red LED or light to indicate
that the door could not be opened, and if inverted could be connected to a
green LED or light.
To configure an output for door interlock.
1. In Full Engineer mode, select Settings>X-BUS>Expanders.
2. In the Expander Configuration page, click on the Change Type button for the
required output.
3. Select Door as the output type.
4. Select the required door and Interlocked as the output type.
15.8.4 Adding an area group
You can use area groups for configuring multiple areas. So the configuration must
not be done for every single area.
Only if the option (multiple) Areas is activated.
Select Settings > System > Area groups.
Vista de pagina 180