The Analysed Attribute must be set for a zone if that zone is wired with an
inertia sensor. The Pulse count and Gross attack values should be
programmed for each inertia sensor on the system in accordance with the
results of a simple calibration of the device.
Pulse count trigger level for analysed inertia sensors.
Gross attack trigger level for analysed inertia sensors
The Final Exit attribute can only be assigned to an Entry/Exit Zone type. Use
this attribute to override the standard process of counting down the exit timer
whenever the system is full set. When all other entry/exit routes in the
premises are closed, fullset the system and close the final exit/entry zone. As
soon as the door is closed the Final Exit time will count down to setting the
system.
A zone with the shunt attribute set will be inhibited whenever a shunt type
zone is opened. This provides a mechanism to group the inhibition of zones
with the opening of the shunt zone type.
This attribute only applies to the FIRE zone type. If this attribute is set, then
activation of the fire zone will only report the activation to the central station.
No alarms will be generated on site.
This attribute only applies to the KEYARM zone type. If set then the setting
state of the building will toggle on openings only.
This attribute only applies to the KEYARM zone type. If this attribute is set
then zone activation will Fullset the system/area. Apply this attribute if it is
intended that the user should only have the ability to FULLSET the system
from a keyarm zone.
This attribute only applies to the KEYARM zone type. If set then zone
activation will Unset the system/area. Apply this attribute if it is intended that
the user should only have the ability to UNSET the system from a keyarm
zone.
This attribute only applies to the KEYARM zone type. If set then zone
activation will Fullset the system/area.
This attribute only applies to the KEYARM zone type. If set then zone
activation will Unset the system/area.
Allows a zone when opened, regardless of the mode to send an alarm to the
ARC in FF, CID, SIA and SIA extended. When areas are selected, the alarm
will only be sent to the ARC to which the area has been assigned to. This
would be a “UA” Unknown Alarm followed by the zone number and text if SIA
extended is selected. It will also send an SMS to the end user and engineer if
select to do so when the unconfirmed alarm filter is selected.
Allows an opening zone to be displayed on the system keypad. The alert led
should also activate. When areas are selected it will only be displayed on the
keypad which is assigned to the area in which the zone has been selected.
The alert may only be displayed on the keypad when the area is in the unset
mode and not in the Part A, Part B and set mode.
Allows an activated zone to operate the buzzer. This will operate the same as
the Tech Zone Display in the different setting modes and on systems with
areas.
Allows the zone to have a programmable delay. The delay is variable from 0
to 9999 seconds and will apply to all Tech Zones. The operation is the same
as the Mains Delay timer, if the zone is closed within the delay time, then no
alarm is sent to the ARC, no SMS is sent to the user and the Technical
Output will not trip.