Siemens SPCK421 Especificaciones Pagina 189

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 296
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 188
Engineer programming via the browser
15
Configuring controller inputs & outputs
189
Siemens AB
A6V10276959
Security Products
18.11.2011
Select the condition under which the latch output is activated:
Entry Time
Output turns on at the end of Exit time and off at the beginning
of Entry time.
Fire Exit
Output turns on if any fire exit zones are active.
Unset
Output turns on if any user unsets system momentary
Alarm Reset
Output turns on if an alarm is reset momentary.
Resetting Alarm
Output turns on during a setting procedure if glass break/smoke
open and not in alarm.
Engineer Exit
Output turns on when an engineer exits from Engineer mode
momentary.
Select the behavior of the output.
On
Output will remain on if auto set is active.
Keypad
Output will follow keypad operation.
Progressive
Output will give progressive warning of auto set.
Pulse Time
Select the duration that the auto set output will remain active
when pulsed.
Vista de pagina 188
1 2 ... 184 185 186 187 188 189 190 191 192 193 194 ... 295 296

Comentarios a estos manuales

Sin comentarios