Engineer programming via the keypad
14 Engineer programming via the keypad
This section provides [Full] Engineer programming options using the LCD keypad
For each menu option, the keypad must be in Full Engineer programming:
1. Enter a valid Engineer PIN (Default Engineer PIN is 1111. For more details,
see Engineering PINs [➙ 68]).
2. Press SELECT for FULL ENGINEER programming.
3. Using the up/down arrow keys, scroll to the desired programming option.
4. To select a programming option using the keypad digits, as shown in the table
below.
5. A quick select function is implemented. Press # to select a parameter (e.g. a
zone attribute). The selected parameter is displayed with a * (e.g. *Inhibit).
Upon completion of the programming options, the keypad displays UPDATED
momentarily.
14.1 SYSTEM STATUS
The System Status feature displays all faults on the system.
To view these faults:
1. Scroll to SYSTEM STATUS.
2. Press SELECT.
The status of the following items is displayed.
Click on each item to display further details.
Displays all areas that have failed to set. Select each area to
display details of why the area failed to set.
Displays current alerts on the system.
Displays all zones on soak test.
Displays zones that are isolated.
Displays voltage and current of battery.
Displays voltage and current of auxillary power.
Comentarios a estos manuales